function intersect - set operationsthe function intersect returns additionally to the vector having the values in the intersection of v1 and v2 an
function setxor and set function uniquethe function setxor receives two vectors as input arguments and returns a vector having all the values from
evacuation in a hospital - fire protection engineeringan evacuation in a hospital is very unlikely to require anyone to go outside the buildings
hospital inspections - fire protection engineeringthere are a number of sections in nfpa101 that deal with health care premises some for existing
evacuation of a high rise building - means of escapeevacuation of a high rise building is likely to be split into two or more phases initially
fire fighting operations - high rise buildingsinlets that allow the fire service to supplement to water to the sprinklers and to the fire mains are
sprinkler installations in high rise buildingsthe staircases in high rise buildings need extra protection against fire it can take a long time
high rise buildingshigh rise buildings have their own particular requirements for fire safety and for fire fighting means of escape rely on most
smoke control - fire protection engineeringsmoke control is a complex subject and requires a course of at least one whole week to begin to understand
means of escape from trains - railway inspectionsthe means of escape from trains is also considered in nfpa130
fire safety management on railway stationsstorage tanks are not allowed above underground structures or within
fire evacuation - railway inspectionsfire evacuation signals should be given by voice messages and these must be easily understood by the
railway inspections - fire safety managementrailway premises can be anything from small open air stations to large underground complexes and the fire
limited travel distances - means of escapeare travel distances within the maximum allowable distances published in the guidanceis there good
protected escape routes - fire protection engineeringprotected escape routes does the fire resistance fully enclose the protected routesdo the
alternative escape routesdoes everyone have access to the alternative routes or do some people have no choice about which way they goare all the
means of escape - place of safetythe means of escape in a building are often supplemented by a fire warning system that may or may not include
limiting travel distances - means of escapesome buildings or parts of buildings do not have alternative exits and do not have protected escape routes
providing fire resistantif the building does not provide everyone with alternative exit routes then it may be acceptable for people to pass the fire
providing alternative escape routesthe first thing to check is if everyone can turn away from the fire and move safely away from itfor this to be the
principle of means of escapethe means of escape with which a building is provided are simply the ways out of the building that can be safely used in
industrial buildings inspectionsfire safety within industrial buildings falls largely within the scope of more general precautions and
inspecting a sprinkler systemswhen inspecting a building that has sprinklers fitted it is not easy to check that the correct water pressure and flow
smoke control systemwhere smoke control is installed in a building it is usual for there to also be sprinkler protection to the building and its
sprinkler system - fire protection engineeringsprinkler systems may be installed in a building to achieve a number of different objectives very