Hamming windows and Kaiser Window

Write the difference between Hamming windows and Kaiser Window?

E

Expert

Verified

Hamming window :

a) The main lobe width is equal to 8π/N and peak side lobe level is –41dB.

b) The low pass FIR filter developed will have first side lobe peak of –53 dB

Kaiser window :

a) The major lobe width, peak side lobe level may be varied by changing the parameter α and N.

b) The side lobe peak can be altered by varying the parameter α.