Free Vibration of MDOF Systems

Why free vibration takes place at MDOF system?

E

Expert

Verified

Free Vibration of MDOF Systems:

Free vibration take place at natural frequencies of the system and, in general, the motion will consist of several simultaneous oscillations at the various natural frequencies of the system.

However, under certain specific conditions, all the coordinates will undergoes harmonic motion corresponding to one of the normal frequencies of the system.

When such motion take place, the motion is called the principal mode of vibration, or the normal mode of vibration.

   Related Questions in Mechanical Engineering

  • Q : Static and Dynamic load What are Static

    What are Static and Dynamic load and what are their significant dynamic effects?

  • Q : Problem on motion of the system (a) A

    (a) A plane moving at a constant velocity, V, crashes into a building as shown in figure below. Due to the design against plane crash of that building, neither major damage nor explosion occurs but the building vibrates after the crash. Assuming that the building can

  • Q : Conformance to standards in product

    Conformance to standards and specifications: These are standards laid down by national and international authorities. For instance, in Canada there is the Standards Council of Canada (SCC). The United States has many standards bodies including MIL (US

  • Q : Mechanical Systems Reliability -

    Mechanical Systems Reliability, MP3701 Your assignment must be submitted electronically via eLe

  • Q : Cetane Number and Octane Number

    Describe the term Cetane Number and the Octane Number?

  • Q : State Concurrent Engineering Concurrent

    Concurrent Engineering has happened primarily as a result of the need to shorten product development times, but improving product quality and reducing product life-cycle costs are important considerations. Some companies have even gone to the extent o

  • Q : MECHANICAL ENGINEERING DESIGN KINDLY

    KINDLY SEND ME MATERIAL ON "MULTISTAGE SPUR GEAR DESIGN OPTIMISATION USING RAY DIAGRAMS"

  • Q : Problem on work of compression A diesel

    A diesel engine operates devoid of a spark plug by using the high-temperature gas produced throughout the compression stage to ignite the fuel. During a typical compression, pure air that is originally at 21 °C and 0.95 bar is reversibly and adiabatically compress

  • Q : Solution A pump station has been

    A pump station has been designed to lift water out of a 6 metre deep pit (vented to atmosphere) via a centrifigual pump mounted at ground level. Liquid conditions 20OC Suction pipe work losses 2.0 metres NPSH safety factor 5.0 kPa Vapor pressure @ 20oC 0.25 metres (a) Calculat

  • Q : Problem on discharge of water In the

    In the below system, d = 6 in., D = 12 in., Δz1 = 6 ft, and Δz2 = 12 ft. The discharge of water in the given system is 10 cfs. Is the machine a turbine or a pump ? Determine the pressures at points A and B? Neglect head losses. Suppos